CPi Biotech relies on low shear, low pulsation pumps for its bioprocess skids
CPi Biotech is using a range of peristaltic pumps for transfer, filling and filtration
Case Study
Call +44 1326 370 370
The 300 series combines performance, practicality and design. With its iconic flip-top design it is an industry standard OEM product in medical device, biotechnology and diagnostic applications, and very popular in many other applications too.
Motor types | DriveSure brushless DC motor, Fixed speed DC motor, NEMA 24 stepper motor, Synchronous AC motor, Variable speed brushless DC motor |
Pumphead options | 313D, 313D2, 314D, 314D2 |
Standards | BS EN 55011-2016+A2-2021, BS EN 61010-1, BS EN IEC 61326-1-2021, CAN/CSA C22.2 No 61010-1, CE, CSA C22.2 No. 61010-1-12/AMD1:2018, EN 61010-1:2010/A1:2019, FCC 47CFR (Part 15), IEC 61010-1, IEC 61010-1:2010/AMD1:2016, RoHS, UL 61010-1, UL 61010-1:2012/R:2 |
Technical Summary table lists features available within the range. See ‘Specifications’ tab for model specific information.
Flow rates (ml/min) Tubing 1.6 mm wall | ||||
---|---|---|---|---|
Tube bore (mm) | 313D pumphead | 314D pumphead | ||
Speed (rpm) | ||||
8 | 408 | 8 | 408 | |
0.5 | 0.24 | 12 | 0.24 | 12 |
0.8 | 0.56 | 29 | 0.48 | 24 |
1.6 | 2.20 | 112 | 2.00 | 102 |
3.2 | 8 | 408 | 6.80 | 350 |
4.8 | 18 | 900 | 15 | 780 |
6.4 | 29 | 1500 | 24 | 1224 |
8.0 | 75 | 2040 | 32 | 1632 |
Flow rates are for guidance only at 0 bar. Always test pumphead flow capability in the relevant fluid system
Flow rates (ml/min) Tubing 2.4 mm wall | ||||
---|---|---|---|---|
Tube bore (mm) | 313D pumphead | 314D pumphead | ||
Speed (rpm) | ||||
8 | 408 | 8 | 408 | |
0.5 | 0.24 | 12 | 0.24 | 12 |
0.8 | 0.56 | 29 | 0.48 | 24 |
1.6 | 2.20 | 112 | 2.00 | 102 |
3.2 | 8 | 408 | 6.80 | 350 |
4.8 | 18 | 900 | 15 | 780 |
6.4 | 29 | 1500 | 24 | 1224 |
Flow rates are for guidance only at 0 bar. Always test pumphead flow capability in the relevant fluid system
Flow Rate (mL/min) by tube bore based on 0.1 rpm (Min) to 410 rpm (Max) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pumphead | 0.5 mm | 0.8 mm | 1.6 mm | 3.2 mm | 4.8 mm | 6.4 mm | 8.0 mm | |||||||
Min | Max | Min | Max | Min | Max | Min | Max | Min | Max | Min | Max | Min | Max | |
313D | 0.003 | 12.2 | 0.007 | 29.1 | 0.027 | 112.5 | 0.100 | 410 | 0.221 | 904 | 0.368 | 1507 | 0.500 | 2050 |
314D | 0.003 | 12.1 | 0.006 | 24.1 | 0.025 | 102.5 | 0.086 | 352 | 0.191 | 784 | 0.300 | 1230 | 0.400 | 1640 |
313D2 | 0.003 | 12.1 | 0.007 | 29.1 | 0.027 | 112.5 | 0.100 | 410 | 0.221 | 904 | 0.368 | 1507 | ||
314D2 | 0.003 | 12.1 | 0.006 | 24.1 | 0.025 | 102.5 | 0.086 | 352 | 0.191 | 784 | 0.300 | 1230 |
Performance data is based on a 48 V DC power supply, pumping water, with 0 bar inlet and discharge pressure. Actual performance is dependent on power supply voltage (DriveSure range 12 V to 48 V DC). For further information contact your local Watson-Marlow representative.
313/314 VDL pumps — Flow rates (ml/min) | ||
---|---|---|
Tube bore (mm) | VDL 24VDC | |
Speed (rpm) | ||
100 | 350 | |
0.5 | 3.00 | 10.5 |
0.8 | 6.00 | 21.0 |
1.6 | 26.0 | 91.0 |
3.2 | 100 | 350 |
4.8 | 220 | 770 |
6.4 | 360 | 1260 |
8.0 | 500 | 1760 |
314 flowrates are approximately 85 % of 313 flow rates
Marprene tubing 1.6 mm wall, zero pressure and no suction lift
Nominal flow rates may vary +/-10 %
313/314 VBM pumps — Flow rates (ml/min) | |||
---|---|---|---|
Tube bore (mm) | VBM 24VDC | ||
Speed (rpm) | |||
100 | 190 | 360 | |
0.5 | 3.4 | 6.5 | 12 |
0.8 | 7.0 | 14 | 26 |
1.6 | 27 | 52 | 100 |
3.2 | 100 | 190 | 360 |
4.8 | 420 | 790 | |
6.4 | 360 | 685 | 1296 |
8.0 | 500 | 950 | 1800 |
314 flowrates are approximately 85 % of 313 flow rates
Marprene tubing 1.6 mm wall, zero pressure and no suction lift
Nominal flow rates may vary +/-10 %
313/314 FAM pumps — Flow rates (ml/min) | |||||||
---|---|---|---|---|---|---|---|
Tube bore (mm) | FAM 50Hz | FAM 60Hz | |||||
Speed (rpm) | |||||||
37 | 75 | 145 | 290 | 42 | 85 | 170 | |
0.5 | 1.3 | 2.6 | 5.0 | 10 | 1.4 | 3.0 | 6.0 |
0.8 | 2.6 | 5.4 | 10 | 21 | 3.0 | 6.0 | 12 |
1.6 | 10 | 20 | 39 | 79 | 11 | 23 | 46 |
3.2 | 37 | 75 | 145 | 290 | 42 | 85 | 170 |
4.8 | 80 | 165 | 320 | 640 | 90 | 190 | 375 |
6.4 | 130 | 270 | 520 | 1045 | 150 | 305 | 610 |
8.0 | 185 | 375 | 725 | 1450 | 210 | 425 | 850 |
314 flowrates are approximately 85 % of 313 flow rates
Marprene tubing 1.6 mm wall, zero pressure and no suction lift
Nominal flow rates may vary +/-10 %
313/314 FDM pumps — Flow rates (ml/min) | ||||
---|---|---|---|---|
Tube bore (mm) | FDM 12/24VDC | |||
Speed (rpm) | ||||
45 | 90 | 175 | 350 | |
0.5 | 1.5 | 3.0 | 6.0 | 12 |
0.8 | 3.2 | 6.4 | 13 | 25 |
1.6 | 12 | 24 | 48 | 95 |
3.2 | 45 | 90 | 175 | 350 |
4.8 | 100 | 198 | 385 | 770 |
6.4 | 160 | 325 | 630 | 1260 |
8.0 | 225 | 450 | 875 | 1750 |
314 flowrates are approximately 85 % of 313 flow rates
Marprene tubing 1.6 mm wall, zero pressure and no suction lift
Nominal flow rates may vary +/-10 %
300 DriveSure ADC/En/Pn | |
Motor types | NEMA 24 stepper motor |
Pumphead options | 313D, 313D2, 314D, 314D2 |
Flow rate range | 0.003 ml/min to 2050 ml/min |
Operating speed range | 0.1 rpm to 410 rpm |
Speed Resolution | 0.1 rpm |
Supply voltage | 12 V to 48 V DC |
Operating temperature range | 5 °C to 40 °C |
Operating temperature range | 41 °F to 104 °F |
Rated Power | 75 W |
Control options | 0–10 V, 2–2000 Hz, 4–20 mA, EtherNet/IP™, Fixed speed, Prime speed, PROFINET® |
Alarms | Cover-open, Hardware fault, Over current, Over temperature, Software fault, Speed, Stall, Under/over voltage |
Outputs | Fault, Tacho |
External Inputs | Prime switch |
Weight | 1.7 - 2.4 kg |
Weight | 3.748 - 5.291 lbs |
Location | Indoor, Enclosure |
Ingress Protection | IP66 capable panel sealing |
Humidity | 80 % up to 31 °C (88 °F), decreasing linearly to 50 % at 40 °C (104 °F) |
Noise | <60 dB(A) |
Max. altitude | 2000 m |
Max. altitude | 6561 ft |
Standards | BS EN 55011-2016+A2-2021, BS EN IEC 61326-1-2021, CSA C22.2 No. 61010-1-12/AMD1:2018, EN 61010-1:2010/A1:2019, FCC 47CFR (Part 15), IEC 61010-1:2010/AMD1:2016, UL 61010-1:2012/R:2019-07 |
Certification and compliance | CB Certificate, EMC, NRTL certification |
Compatible tubing bore size | 0.5, 0.8, 1.6, 3.2, 4.8, 6.4, 8 mm |
Compatible tubing wall thickness | 1.6, 2.4 mm |
Motor | A | B | C | D | E | F | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm | in | mm | in | mm | in | mm | in | mm | in | mm | in | |
Standard NEMA 24 stepper motor (most applications) | 101 | 3.98 | 93 | 3.68 | 128 | 5.04 | 160 | 6.30 | 92 | 3.62 | 103 | 4.06 |
High torque NEMA 24 stepper motor (demanding applications) | 190 | 7.48 | 123 | 4.82 |
The 300 series has two drive options comprising a standard motor which covers most applications and a longer motor for applications requiring higher torque. Motor choice considerations include tube size, material, speed and pressure.
Specify motor type in product code or contact your local Watson-Marlow representative
Pumphead body assembly | Glass filled polypropylene, Polyacrylamide—IXEF (PARA), Stainless steel |
Pumphead rotor assembly | Electroless nickel plated hardened steel, Glass filled Nylon |
Pumphead roller assembly | MoS2 filled Nylon 6 (Nylatron) |
Motor | Aluminium, Plasma nitride coated stainless steel |
Controller Housing | ABS/PC, Aluminium |
Mounting plate assembly | Nitrile, Polyacrylamide (PARA)-halogen free, UL94 V-0 rated, Thermoplastic elastomer (TPE) |
Information listed covers the complete range. For detailed specifications of individual models/components refer to product reference manual or contact WMFTS representative.
Pump product codes | ||
---|---|---|
Description | Motor control | Product code |
PMD24CV300 | 0 - 10 V | Contact your local Watson-Marlow representative |
PMD24CI300 | 4 - 20 mA | Contact your local Watson-Marlow representative |
PMD48CV300 | 0 - 10 V | Contact your local Watson-Marlow representative |
PMD48CI300 | 4 - 20 mA | Contact your local Watson-Marlow representative |
For mounting plate options, test leads and further pumphead configurations, contact your local Watson-Marlow sales representative
Pump product codes | ||||
---|---|---|---|---|
Description | Supply voltage | Speed (rpm) | Number of channels | Product code |
313VDL/D | 24 VDC | 100 | 040.NP10.3D0 | |
24 VDC | 350 | 040.NU10.3D0 |
Silicone 8.0 mm no backpressure
Marprene max 6.4 mm no backpressure
Pump product codes | ||||
---|---|---|---|---|
Description | Supply voltage | Speed (rpm) | Number of channels | Product code |
313VBM/D | 24 VDC | 100 | 3 | 040.NP23.010 |
24 VDC | 190 | 2 | 040.NS23.010 | |
24 VDC | 360 | 1 | 040.NV23.010 |
Silicone 8.0 mm no backpressure
Marprene max 6.4 mm no backpressure
Pump product codes | ||||
---|---|---|---|---|
Description | Supply voltage | Speed (rpm) | Number of channels | Product code |
313FAM/D | 230 VAC, 50 Hz | 37 | 6 | 040.AG23.010 |
115 VAC, 60 Hz | 42 | 4 | 040.EH23.010 | |
230 VAC, 50 Hz | 75 | 4 | 040.AN23.010 | |
115 VAC, 60 Hz | 85 | 2 | 040.EP23.010 | |
230 VAC, 50 Hz | 145 | 2 | 040.AQ23.010 | |
115 VAC, 60 Hz | 170 | 1 | 040.ER23.010 | |
230 VAC, 50 Hz | 290 | 1 | 040.AU23.010 |
Silicone 8.0 mm no backpressure
Marprene max 6.4 mm no backpressure
Pump product codes | ||||
---|---|---|---|---|
Description | Supply voltage | Speed (rpm) | Number of channels | Product code |
313FDM/D | 12 VDC | 45 | 6 | 040.CH23.010 |
24 VDC | 45 | 6 | 040.DH23.010 | |
12 VDC | 90 | 4 | 040.CP23.010 | |
24 VDC | 90 | 4 | 040.DP23.010 | |
12 VDC | 175 | 2 | 040.CR23.010 | |
24 VDC | 175 | 2 | 040.DR23.010 | |
12 VDC | 350 | 1 | 040.CV23.010 | |
24 VDC | 350 | 1 | 040.DV23.010 |
Silicone 8.0 mm no backpressure
Marprene max 6.4 mm no backpressure
0 = Complete pump | 4 = ADC | 1 = 1 m (3.28 ft) cable | 0 = No pumphead | A = Standard NEMA 24 stepper motor | 0 = No pumphead | 0 = No pumphead | 0 = No pumphead |
6 = Drive only | 8 = En (EtherNet/IPTM) | 3 = 3 m (9.84 ft) cable | 1 = Standard colour | C = High torque NEMA 24 stepper motor | C = 313D/313D2 | V = Variable | 1 = 1.6 mm |
9 = Pn (PROFINET®) | 2 = Black | D = 314D/314D2 | C = Fixed 0.5 mm to 1.6 mm bore | 2 = 2.4 mm | |||
3 = White | F = Fixed 3.2 mm bore | ||||||
K = Fixed 4.8 mm bore | |||||||
N = Fixed 6.4 mm to 8.0 mm bore |
Accessories and Spares | |
---|---|
Product | Product code |
300 Series DriveSure Sealed Mounting Plate / Sensor | 039.IPMP.DVS |
DriveSure cable pack - 24 V power supply/USB-C - trials only * | 009.24CP.DVS |
DriveSure cable pack - 48 V power supply/USB-C - trials only * | 009.48CP.DVS |
1 m Power Cable DriveSure ADC/En/Pn | 009.1PW.DVS |
3 m Power Cable DriveSure ADC/En/Pn | 009.3PW.DVS |
1 m Control Cable DriveSure ADC | 009.1CC.DVS |
3 m Control Cable DriveSure ADC | 009.3CC.DVS |
Ethernet Cable, RJ45 to RJ45, CAT 5e SHIELDED, 3m | 059.9123.000 |
PROFINET® Cable, RJ45 to RJ45, CAT 5e SHIELDED, 3m | 059.9128.000 |
*Cable packs do not include mains power lead. If required, order power leads suitable for your region.
CPi Biotech is using a range of peristaltic pumps for transfer, filling and filtration
Case Study
Using dispensing and dosing pumps from WMFTS have resulted in less chemical waste for St. Eval
Case Study
Pumps were selected for their high chemical resistance and capability of dosing very small...
Case Study
Iconic flip-top pumps for medium flows to 2,000 ml/min. Extendable up to 6 channels.
Pumpheads
High accuracy microcassettes for manifold tubing for flow rates up to 53 ml/min.
Pumpheads
Speed control boards with manual, remote or auto control. External potentiometer.
Pumps - panel mount pumps
Thermoplastic tubing with long peristaltic life and low permeability. 5 ºC to 80 ºC (23 ºF to 176 ºF).
Tubing - peristaltic
Platinum-cured silicone tubing with ultra smooth bore and excellent flow stability. -20 ºC to 80 ºC (-4 ºF to 176 ºF).
Tubing - peristaltic
Iconic flip-top pumps for flows up to 500 ml/min. Accurate flow performance to medium pressures.
Pumps - panel mount pumps
Our smallest pump for micro flows from 30 μl/min to 30 ml/min.
Pumps - panel mount pumps
One to three channel pumps for low flows to 82 ml/min. Supports three different tubing formats.
Pumps - panel mount pumps
One to eight channel pumps for medium flows to 200 ml/min. Compact design and Luer connectors for 'fit and forget' applications.
Pumps - panel mount pumps
Flexible, high quality designs which are well suited to custom projects.
Pumps - panel mount pumps
Precision pump for surgical cooling applications which require flow control to specified, high pressures.
Pumps - panel mount pumps
Durable, single channel pumps for high flows to 3,500 ml/min. Supports continuous tubing and Loadsure elements for high pressures.
Pumps - panel mount pumps
To order a product or ask a question