620Di pumps combine industrial power and durability with unrivalled precision, pumping up to 18 L/min and achieving pressures up to 4 bar. The pump can store 50 dispensing programs using the simple screen-keypad interface. The pump outputs batch records for cGMP requirements.
Filling volume range | Up to 500ml in 2.4s, Up to 500ml in 3.0s ml |
Accuracy | ±0.5 % |
Technical Summary table lists features available within the range. See ‘Specifications’ tab for model specific information.
Flow ranges (L/min) | Y element tubing | Continuous tubing | ||||
---|---|---|---|---|---|---|
(over 0.1 to 265rpm speed range) | (single channel) | (flow per channel - max of 2 channels) | ||||
Tubing material | 8.0mm | 12.0mm | 16.0mm | 8.0mm | 12.0mm | 16.0mm |
Pumpsil silicone | 0.002-4.6 | 0.003-8.5 | 0.005-11.5 | 0.001-2.3 | 0.002-4.3 | 0.003-5.8 |
Marprene, Bioprene | 0.002-4.6 | 0.003-8.5 | 0.005-11.5 | 0.001-2.3 | 0.002-4.3 | 0.003-5.8 |
Dose sizes | |||
---|---|---|---|
Tube bore | 8.0mm | 12.0mm | 16.0mm |
Minimum possible dose | 8ml | 16ml | 22ml |
Minimum recommended | 84ml | 161ml | 218ml |
Flow ranges (L/min) | Y element tubing | Continuous tubing | ||||
---|---|---|---|---|---|---|
(over 0.1 to 265rpm speed range) | (single channel) | (flow per channel - max of 2 channels) | ||||
Tubing material | 8.0mm | 12.0mm | 16.0mm | 8.0mm | 12.0mm | 16.0mm |
Pumpsil silicone | 0.002-4.6 | 0.003-8.5 | 0.005-11.5 | 0.001-2.3 | 0.002-4.3 | 0.003-5.8 |
Marprene, Bioprene | 0.002-4.6 | 0.003-8.5 | 0.005-11.5 | 0.001-2.3 | 0.002-4.3 | 0.003-5.8 |
STA-PURE PCS | 0.002-5.2 | 0.003-9.0 | 0.005-12.4 | 0.001-2.6 | 0.002-4.5 | 0.003-6.2 |
620LG dose sizes (STA-PURE PCS®, STA-PURE PFL®) | |||
---|---|---|---|
Tube bore | 8.0mm | 12.0mm | 16.0mm |
Minimum possible dose | 10ml | 17ml | 23ml |
Minimum recommended | 99ml | 167ml | 234ml |
Flow ranges (L/min) | Continuous tubing | |||
---|---|---|---|---|
(over 0.1 to 265rpm speed range) | 620R (2 rollers) | |||
Tubing material | 6.4mm | 9.6mm | 12.7mm | 15.9mm |
Marprene TL, Bioprene TL | 0.001-3.4 | 0.003-6.6 | 0.004-11 | 0.01-12 |
Pumpsil silicone | 0.001-3.2 | 0.003-7.2 | 0.004-11 | 0.01-15 |
STA-PURE PCS | 0.001-3.2 | 0.003-6.6 | 0.004-11 | 0.01-16 |
Dose sizes | ||||
---|---|---|---|---|
Tube bore | 6.4mm (1/4”) | 9.6mm (3/8”) | 12.7mm (1/2”) | 15.9mm (5/8”) |
Minimum possible dose | 6ml | 14ml | 21ml | 28ml |
Minimum recommended | 60ml | 136ml | 208ml | 283ml |
Flow ranges (L/min) | LoadSure™ element tubing | |
---|---|---|
(over 0.1 to 265rpm speed range) | 620RE (2 rollers) | |
Tubing material | 12mm | 17mm |
Marprene TM, Bioprene TM | 0.004-9.8 | 0.01-16 |
Marprene TL, Bioprene TL | 0.004-9.8 | 0.01-18 |
Pumpsil silicone | 0.004-10 | 0.01-16 |
STA-PURE PCS | 0.004-11 | 0.01-18 |
620RE dose sizes | ||
---|---|---|
Tube bore | 12mm | 17mm |
Minimum possible dose | 19ml | 30ml |
Minimum recommended | 189ml | 302ml |
Flow ranges (L/min) | LoadSure™ element tubing | |
---|---|---|
(over 0.1 to 265rpm speed range) | 620REH (2 rollers) | |
Tubing material | 12mm | 17mm |
Marprene TM, Bioprene TM | 0.003-8.3 | 0.004-11 |
Marprene TL, Bioprene TL | 0.003-8.3 | 0.005-12 |
Pumpsil silicone | 0.003-8.7 | 0.004-11 |
STA-PURE PCS | 0.003-9.0 | 0.010-13 |
620RE4 dose sizes | ||
---|---|---|
Tube bore | 12mm | 17mm |
Minimum possible dose | 16ml | 21ml |
Minimum recommended | 164ml | 208ml |
620Di and 620DiN with 620L pumphead | 620Di and 620DiN with 620LG pumphead | 620Di and 620DiN with 620R pumphead | 620Di and 620DiN with 620RE pumphead | 620Di and 620DiN with 620REH pumphead | |
---|---|---|---|---|---|
Filling volume range | Up to 500ml in 2.4s ml | Up to 500ml in 2.4s ml | Up to 500ml in 3.0s ml | Up to 500ml in 3.0s ml | Up to 500ml in 3.0s ml |
Accuracy | ±0.5 % | ±0.5 % | ±0.5 % | ±0.5 % | ±0.5 % |
Ingress Protection | IP31, IP66, NEMA 2, NEMA 4X | IP31, IP66, NEMA 2, NEMA 4X | IP31, IP66, NEMA 2, NEMA 4X | IP31, IP66, NEMA 2, NEMA 4X | IP31, IP66, NEMA 2, NEMA 4X |
Operating temperature range | 5 °C to 40 °C | 5 °C to 40 °C | 5 °C to 40 °C | 5 °C to 40 °C | 5 °C to 40 °C |
Operating temperature range | 40 °F to 104 °F | 40 °F to 104 °F | 40 °F to 104 °F | 40 °F to 104 °F | 40 °F to 104 °F |
Speed control ratio | 2650:1 | 2650:1 | 2650:1 | 2650:1 | 2650:1 |
Humidity | (Condensing) 10 to 100 % RH, (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F) | (Condensing) 10 to 100 % RH, (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F) | (Condensing) 10 to 100 % RH, (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F) | (Condensing) 10 to 100 % RH, (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F) | (Condensing) 10 to 100 % RH, (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F) |
Noise | <70dB(A) at 1m | <70dB(A) at 1m | <70dB(A) at 1m | <70dB(A) at 1m | <70dB(A) at 1m |
Standards | CE, cETLus | CE, cETLus | CE, cETLus | CE, cETLus | CE, cETLus |
Power supply | 100 V to 120 V, 200 V to 240 V, 50/60 Hz, Single-phase | 100 V to 120 V, 200 V to 240 V, 50/60 Hz, Single-phase | 100 V to 120 V, 200 V to 240 V, 50/60 Hz, Single-phase | 100 V to 120 V, 200 V to 240 V, 50/60 Hz, Single-phase | 100 V to 120 V, 200 V to 240 V, 50/60 Hz, Single-phase |
Weight | 24.3 - 25.2 kg | 24.3 - 25.2 kg | 19.6 - 20.5 kg | 19.6 - 20.5 kg | 20.1 - 21 kg |
Weight | 53.6 - 55.6 lbs | 53.6 - 55.6 lbs | 43.2 - 45.2 lbs | 43.2 - 45.2 lbs | 44.3 - 46.3 lbs |
Accessories | Footswitch, handswitch, RS232 cable, batch records cable | Footswitch, handswitch, RS232 cable, batch records cable | Footswitch, handswitch, RS232 cable, batch records cable | Footswitch, handswitch, RS232 cable, batch records cable | Footswitch, handswitch, RS232 cable, batch records cable |
Compatible tubing size | 12.0 mm ID, 16.0 mm ID, 4.0 mm wall thickness, 8.0 mm ID | 12.0 mm ID, 16.0 mm ID, 4.0 mm wall thickness, 8.0 mm ID | 12.0 mm ID, 12.7 mm ID, 15.9 mm ID, 17.0 mm ID, 6.4 mm ID, 9.6 mm ID | 12.0 mm ID, 12.7 mm ID, 15.9 mm ID, 17.0 mm ID, 6.4 mm ID, 9.6 mm ID | 12.0 mm ID, 12.7 mm ID, 15.9 mm ID, 17.0 mm ID, 6.4 mm ID, 9.6 mm ID |
Bearings | Carbon steel |
Casework | Pressure die-cast aluminium LM24, Pressure die-cast aluminium LM6 |
Keypad/HMI | Polyester |
Pumphead roller assembly | Nylatron, Stainless steel |
Functionality | 620Di | 620DiN |
---|---|---|
Enclosure - ingress protection rating | IP31 | IP66 |
Manual control | ||
Digital speed control with simple calibration to display flow | ✔ | ✔ |
Choice of flow rate display; metric or imperial units | ✔ | ✔ |
Numeric keypad for entry of speed, flow or PIN code | ✔ | ✔ |
Remote control | ||
Run/stop, direction change, auto/manual mode, leak detector input (via contact closure or 5V TTL to 24V industrial logic) | ✔ | ✔ |
Remote operation of dosing (foot/handswitch or logic input) | ✔ | ✔ |
Four programmable digital status outputs through 5V TTL to 24V industrial logic | ✔ | |
Analogue speed feedback | ||
Tachometer output; 0-1478Hz | ✔ | ✔ |
Digital communication | ||
Digital network serial control RS232 RS485 | RS232 | RS485 |
Specialist dispensing functionality | ||
Drip control feature (momentary direction reverse at end of dose) | ✔ | ✔ |
Ramp control to improve accuracy and avoid splashing or frothing | ✔ | ✔ |
Export of batch records to PC or printer for cGMP requirements RS232 | RS232 | |
Dual operator/supervisor PIN code protection of pump settings | ✔ | ✔ |
Product codes | ||||||
---|---|---|---|---|---|---|
620L pumphead | Accessories | |||||
Pumphead only | 063.4603.000 | Footswitch | Handswitch | RS232 cable | Batch records cable | |
IP31/NEMA 2 wipe-down pumps | IP31 | IP31 | IP31 | IP31 | ||
620Di/L | 060.4171.5L0* | 059.3002.000 | 059.3022.000 | 059.3121.000 | 059.3125.000 | |
* Replace last zero with A, E, U, K, R, D, Z or C for 2.8m American, European, United Kingdom, Australian, Argentinian, South African, Chinese or Swiss mains plug | ||||||
IP66/NEMA 4X wash-down pumps | IP55 | IP65 | ||||
620DiN/L | 060.417N.5L0** | 069.5231.000 | n/a | n/a | n/a | |
** Replace last zero with A, C, K, R or Z plug type |
Y element tubing | Continuous tubing | |||||
---|---|---|---|---|---|---|
Bore size (4.0mm wall thickness) | 8.0mm | 12.0mm | 16.0mm | 8.0mm | 12.0mm | 16.0mm |
Tubing material | ||||||
Pumpsil silicone | 913.AE80.K40 | 913.A12E.K40 | 913.A16E.040 | 913.A080.040 | 913.A120.040 | 913.A160.040 |
Marprene | 902.E080.K40 | 902.E120.K40 | 902.E160.040 | 902.0080.040 | 902.A120.040 | 902.0160.040 |
Bioprene | 933.E080.K40 | 933.E120.K40 | 933.E160.040 | 933.0080.040 | 933.A120.040 | 933.0160.040 |
Clamp set for continuous tube | 069.4001.000 |
Product codes | |||||
---|---|---|---|---|---|
620LG pumphead | Accessories | ||||
Pumphead only | 063.4623.000 | Footswitch | Handswitch | RS232 cable | Batch records cable |
IP31/NEMA 2 wipe-down pumps | IP31 | IP31 | IP31 | IP31 | |
620Di/LG | 060.4171.5G0* | 059.3002.000 | 059.3022.000 | 059.3121.000 | 059.3125.000 |
* Replace last zero with A, E, U, K, R, D, Z or C for 2.8m American, European, United Kingdom, Australian, Argentinian, South African, Chinese or Swiss mains plug | |||||
IP66/NEMA 4X wash-down pumps | IP55 | IP65 | |||
620DiN/LG | 060.417N.5G0** | 069.5231.000 | n/a | n/a | n/a |
** Replace last zero with A, C, K, R or Z plug type |
Y element tubing | Continuous tubing | ||||||
---|---|---|---|---|---|---|---|
Bore size (4.0mm wall thickness) | 8.0mm | 12.0mm | 16.0mm | 8.0mm | 12.0mm | 16.0mm | |
Tubing material | |||||||
Pumpsil silicone | 913.AE80.K40 | 913.A12E.K40 | 913.A16E.040 | 913.A080.040 | 913.A120.040 | 913.A160.040 | |
Marprene | 902.E080.K40 | 902.E120.K40 | 902.E160.040 | 902.0080.040 | 902.A120.040 | 902.0160.040 | |
Bioprene | 933.E080.K40 | 933.E120.K40 | 933.E160.040 | 933.0080.040 | 933.A120.040 | 933.0160.040 | |
STA-PURE PCS | 961.E080.K40 | 961.E120.K40 | 961.E160.040 | ||||
Clamp set for continuous tube | 069.4001.000 | ||||||
NB: 4 bar pressure capability with STA-PURE PCS elements |
Pumpheads | Accessories | ||||
---|---|---|---|---|---|
620R MkII head | Footswitch | Handswitch | RS232 cable | Batch records cable | |
Pumphead only | 063.4211.000 | ||||
IP31/NEMA 2 wipe-down pumps | IP31 | IP31 | IP31 | IP31 | |
620Di/R | 060.4171.020* | 059.3002.000 | 059.3022.000 | 059.3121.000 | 059.3125.000 |
* Replace last zero with A, E, U, K, R, D, Z or C for 2.8m American, European, United Kingdom, Australian, Argentinian, South African, Chinese or Swiss mains plug | |||||
IP66/NEMA 4X wash-down pumps | IP55 | ||||
620DiN/R | 060.417N.020** | 069.5231.000 | n/a | n/a | — |
** Replace last zero with A, C, K, R or Z plug type |
Tubing | ||||
---|---|---|---|---|
Continuous tubing | ||||
6.4mm | 9.6mm | 12.7mm | 15.9mm | |
STA-PURE PCS | 961.0064.032 | 961.0096.032 | 961.0127.032 | 961.0159.032 |
Bioprene TL | 933.0064.032 | 933.0096.032 | 933.0127.032 | 933.0159.032 |
Marprene TL | 902.0064.032 | 902.0096.032 | 902.0127.032 | 902.0159.032 |
Pumpsil silicone | 913.A064.032 | 913.A096.032 | 913.A127.032 | 913.A159.032 |
NB: 4 bar pressure capability with Sta-Pure PCS |
Pumpheads | Accessories | ||||
---|---|---|---|---|---|
620RE MkII head | Footswitch | Handswitch | RS232 cable | Batch records cable | |
Pumphead only | 063.4231.000 | ||||
IP31/NEMA 2 wipe-down pumps | IP31 | IP31 | IP31 | IP31 | |
620Di/RE | 060.4171.E20* | 059.3002.000 | 059.3022.000 | 059.3121.000 | 059.3125.000 |
* Replace last zero with A, E, U, K, R, D, Z or C for 2.8m American, European, United Kingdom, Australian, Argentinian, South African, Chinese or Swiss mains plug | |||||
IP66/NEMA 4X wash-down pumps | IP55 | ||||
620DiN/RE | 060.417N.E20** | 069.5231.000 | n/a | n/a | — |
** Replace last zero with A, C, K, R or Z plug type |
Tubing | ||||
---|---|---|---|---|
Sanitary LoadSure™ elements (3/4” Tri-clamp PVDF connectors) | Industrial LoadSure™ elements (3/4” Cam & Groove PP connectors) | |||
12mm | 17mm | 12mm | 17mm | |
STA-PURE PCS | 961.0120.PFT | 961.0170.PFT | — | — |
Bioprene TM | 933.P120.PFT | 933.P170.PFT | — | — |
Bioprene TL | 933.0120.PFT | 933.0170.PFT | — | — |
Marprene TM | — | — | 902.P120.PPC | 902.P170.PPC |
Marprene TL | — | — | 902.0120.PPC | 902.0170.PPC |
Pumpsil silicone | 913.A120.PFT | 913.A170.PFT | 913.A120.PPC | 913.A170.PPC |
NB: 4 bar pressure capability with Sta-Pure PCS, Bioprene TM and Marprene TM |
Pumpheads | Accessories | ||||
---|---|---|---|---|---|
620RE4 MkII head | Footswitch | Handswitch | RS232 cable | Batch records cable | |
Pumphead only | 063.4431.000 | ||||
IP31/NEMA 2 wipe-down pumps | IP31 | IP31 | IP31 | IP31 | |
620Di/REH | 060.4171.E40* | 059.3002.000 | 059.3022.000 | 059.3121.000 | 059.3125.000 |
* Replace last zero with A, E, U, K, R, D, Z or C for 2.8m American, European, United Kingdom, Australian, Argentinian, South African, Chinese or Swiss mains plug | |||||
IP66/NEMA 4X wash-down pumps | IP55 | ||||
620DiN/REH | 060.417N.E40** | 069.5231.000 | n/a | n/a | — |
** Replace last zero with A, C, K, R or Z plug type |
Tubing | ||||||||
---|---|---|---|---|---|---|---|---|
Sanitary LoadSure™ elements (3/4” Tri-clamp PVDF connectors) | Industrial LoadSure™ elements (3/4” Cam & Groove PP connectors) | |||||||
12mm | 17mm | 12mm | 17mm | |||||
STA-PURE PCS | 961.0120.PFT | 961.0170.PFT | — | — | ||||
Bioprene TM | 933.P120.PFT | 933.P170.PFT | — | — | ||||
Bioprene TL | 933.0120.PFT | 933.0170.PFT | — | — | ||||
Marprene TM | — | — | 902.P120.PPC | 902.P170.PPC | ||||
Marprene TL | — | — | 902.0120.PPC | 902.0170.PPC | ||||
Pumpsil silicone | 913.A120.PFT | 913.A170.PFT | 913.A120.PPC | 913.A170.PPC | ||||
NB: 4 bar pressure capability with Sta-Pure PCS, Bioprene TM and Marprene TM |
Pharmaceuticals manufacturer Polpharma doubles productivity with peristaltic pump technology.
Case Study
Tubing for accurate filling with excellent dispensing accuracy ± 0.5 %. Eight sizes available.
Single-use assemblies
Dispensing pump for flow rates to 3.5 L/min (55 USGPH) and pressures up to 4 bar (60 psi).
Aseptic filling - benchtop fillers
Tabletop aseptic filling machine for <5 ml to >5000 ml. Accuracy of ±0.5 % on most volumes prevents costly overfilling.
Aseptic filling - benchtop fillers
Tabletop aseptic filling machine for <0.2 ml to >250 ml. Accuracy of ±0.5 % on most volumes prevents costly overfilling.
Aseptic filling - benchtop fillers
To order a product or ask a question