520Di pumps combine industrial power and durability with unrivalled precision, pumping up to 3.5 L/min and achieving pressures up to 2 bar. The pump can store up to 50 dispensing programs using the simple screen-keypad interface. The pump outputs batch records for cGMP requirements.
Accuracy | ±0.5 % |
Technical Summary table lists features available within the range. See ‘Technical specifications’ tab for model specific information.
505L pumphead — Flow rates (ml/min) | ||||||||
---|---|---|---|---|---|---|---|---|
Tube Material | Speed | 1.6mm | 3.2mm | 4.8mm | 6.4mm | 8.0mm | 9.6mm | |
Pumpsil®, GORE® STA-PURE® Pump Tubing-Series PCS, GORE® STA-PURE® Pump Tubing - Series PFL | 0.1-350rpm | 0.04-150 | 0.23-800 | 0.42-1500 | 0.70-2500 | 0.90-3200 | NA | |
Marprene®, Bioprene® | 0.1-350rpm | 0.04-130 | 0.17-500 | 0.38-830 | 0.67-2000 | 1.10-3200 | NA |
505L pumphead recommended dose sizes | |||||||
---|---|---|---|---|---|---|---|
Tube bore | 1.6mm | 3.2mm | 4.8mm | 6.4mm | 8.0mm | 9.6mm | |
maximum speed 350rpm | Minimum dose | 0.9ml | 4.5ml | 8.5ml | 14ml | 18ml | 25ml |
Maximum dose | 15ml | 75ml | 150ml | 250ml | 300ml | 400ml |
520Di and 520DiN | |
---|---|
Accuracy | ±0.5 % |
Ingress Protection | IP31, IP66, NEMA 2, NEMA 4X |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Speed control ratio | 2200:1 |
Humidity | (Condensing) 10 to 100% RH, (Non-condensing) 80% up to 31°C (88°F), decreasing linearly to 50% at 40C (104F) |
Noise | <70dBb(A) at 1m |
Standards | CE, cETLus |
Power supply | 110/230 V, 50/60 Hz, Single-phase |
Weight | 9.82 - 10.7 kg |
Weight | 21.63 - 23.56 lbs |
Compatible tubing size | 1.6 mm ID, 3.2 mm ID, 4.8 mm ID, 6.4 mm ID, 8.0 mm ID, 9.6 mm ID |
Bearings | Stainless steel |
Casework | Pressure die-cast aluminum LM24 |
Keypad/HMI | Polyester |
Pumphead roller assembly | Stainless steel 316 |
Seals | PTFE |
Pump drives | 520Di | 520DiN |
---|---|---|
Enclosure | ||
Ingress protection rating | IP31 | IP66 |
Manual control | ||
Digital speed control with full calibration to display flow | ✔ | ✔ |
Choice of flowrate or speed display | ✔ | ✔ |
Numerical keypad for entry of speed | ✔ | ✔ |
Remote control | ||
Run/Stop, direction change, auto/manual toggle, leak detector input (via contact closure or 5V TTL or 24V industrial logic) | ✔ | ✔ |
Remote operation of Dosestart with instantaneous switch | ✔ | ✔ |
Four programmable digital status outputs through 24V, 30W relays | ✔ | |
Digital communication | ||
Digital network serial control | RS232 | RS485 |
Security | ||
Security code to protect set-up, programs and dose parameters | ✔ | ✔ |
Pump and pumphead product codes | |||
---|---|---|---|
Description | Partcode | Description | Partcode |
505L Low pulse twin channel pumphead | 053.4001.000 | 520Di (IP31) drive only | 056.7171.000* |
505LX Low pulse twin channel extension pumphead | 053.4011.000 | 520DiN (IP66) drive only | 056.717N.000** |
505LG Low pulse twin channel pumphead for STA-PURE® tubing | 053.4010.00G | 505LTC Tube clamp set for 505L pumphead | 059.4001.000 |
* Supplied as 2.4m mains lead without plug. To specify American, European, United Kingdom, Australian, Argentinian or Swiss 2.8m mains lead please specify A, E, U, K, R or C respectively. Replace the last zero with the mains lead code. For example - 050.7131.10A is a 520S/R pump with American mains lead. ** Supplied as 2.4m mains cable without a plug. To specify American mains lead please replace the last zero with A. |
Tube ordering codes | ||||||
---|---|---|---|---|---|---|
Double Y tubing elements for 520DiL dispenser | ||||||
Bore (mm) | Bioprene TL | Marprene TL | Pumpsil | Pumpsil-D | STA-PURE® PCS | STA-PURE® PFL |
1.6 | 933.E016.K24 | 902.E016.K24 | 913.AE16.K24 | 913.DE16.K24 | 960.E016.K24 | 965.E016.K24 |
3.2 | 933.E032.K24 | 902.E032.K24 | 913.AE32.K24 | 913.DE32.K24 | 960.E032.K24 | 965.E032.K24 |
4.8 | 933.E048.K24 | 902.E048.K24 | 913.AE48.K24 | 913.DE48.K24 | 960.E048.K24 | 965.E048.K24 |
6.4 | 933.E064.K24 | 902.E064.K24 | 913.AE64.K24 | 913.DE64.K24 | 960.E064.K24 | 965.E064.K24 |
8 | 933.E080.K24 | 902.E080.K24 | 913.AE80.K24 | 913.DE80.K24 | 960.E080.K24 | 965.E080.K24 |
9.6 | 933.E096.K24 | 902.E096.K24 | 913.AE96.K24 | 913.DE96.K24 |
Tubing for accurate filling with excellent dispensing accuracy ± 0.5 %. Eight sizes available.
Single-use assemblies
WMArchitectTM fill/finish single-use assemblies safeguard your therapeutic during the filling process with a wide range of sterility-assured assembly configurations.
Single-use assemblies
Dispensing pump for flow rates to 4.76 GPM (18 L/min) and pressures up to 60 psi (4 bar).
Aseptic filling - benchtop fillers
Tabletop aseptic filling machine for <0.17 fl oz (5 ml) to >169.07 fl oz (5000 ml). Accuracy of ±0.5 % on most volumes prevents costly overfilling.
Aseptic filling - benchtop fillers
Tabletop aseptic filling machine for <0.2 ml to >250 ml. Accuracy of ±0.5 % on most volumes prevents costly overfilling.
Aseptic filling - benchtop fillers
To order a product or ask a question